ST2 Earth Push In Terminal Block
Product Detail
ST2-2.5 2-2JD
| Type |
ST2-2.5/2-2JD |
| L/W/H |
5.2*68.5*46 mm |
| Rated cross section |
2.5 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
4 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
2.5 mm2 |
| Cover |
ST2-2.5/2-2G |
| Jumper |
UFB 10-5 |
| Marker |
ZB5M |
| Packing unit |
72 |
| Minimum Order Quantity |
72 |
| Weight of each(not include packing box) |
11.5 g |
Dimension
Wiring Diagram
ST2-2.5 2X2JD
Dimension
Wiring Diagram
| Type |
ST2-2.5/2X2JD |
| L/W/H |
5.2*72.4*35.5 mm |
| Rated cross section |
2.5 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
4 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
2.5 mm2 |
| Cover |
ST3-2.5/2X2G |
| Jumper |
UFB 10-5 |
| Marker |
ZB5M |
| Packing unit |
90 |
| Minimum Order Quantity |
90 |
| Weight of each(not include packing box) |
11.5 g |
ST2-2.5-3-3JD
| Type |
ST2-2.5/3-3JD |
| L/W/H |
5.2*104*57 mm |
| Rated cross section |
2.5 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
4 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
2.5 mm2 |
| Cover |
ST2-2.5/3-3G |
| Jumper |
UFB 10-5 |
| Marker |
ZB5M |
| Packing unit |
56 |
| Minimum Order Quantity |
56 |
| Weight of each(not include packing box) |
18.1 g |
Dimension
Wiring Diagram
ST2-2.5JD
Dimension
Wiring Diagram
| Type |
ST2-2.5JD |
| L/W/H |
5.2*48.8*35.5 mm |
| Rated cross section |
2.5 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
4 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
2.5 mm2 |
| Cover |
ST3-G |
| Jumper |
UFB 10-5 |
| Marker |
ZB5M |
| Packing unit |
100 |
| Minimum Order Quantity |
100 |
| Weight of each(not include packing box) |
9 g |
ST2-4 1X2JD
| Type |
ST2-4/1X2JD |
| L/W/H |
6.2*66.8*35.5 mm |
| Rated cross section |
4 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
6 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
4 mm2 |
| Cover |
ST2-4/1X2G |
| Jumper |
/ |
| Marker |
ZB6M |
| Packing unit |
100 |
| Minimum Order Quantity |
100 |
| Weight of each(not include packing box) |
12 g |
Dimension
Wiring Diagram
ST2-4 2-2JD
Dimension
Wiring Diagram
| Type |
ST2-4/2-2JD |
| L/W/H |
6.2*84*46 mm |
| Rated cross section |
4 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
6 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
4 mm2 |
| Cover |
ST2-4/2-2G |
| Jumper |
/ |
| Marker |
ZB6M |
| Packing unit |
100 |
| Minimum Order Quantity |
100 |
| Weight of each(not include packing box) |
18 g |
ST2-4 2X2JD
| Type |
ST2-4/2X2JD |
| L/W/H |
6.2*77.4*35.5 mm |
| Rated cross section |
4 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
6 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
4 mm2 |
| Cover |
ST2-4/2X2G |
| Jumper |
/ |
| Marker |
ZB6M |
| Packing unit |
60 |
| Minimum Order Quantity |
60 |
| Weight of each(not include packing box) |
14 g |
Dimension
Wiring Diagram
ST2-4JD
Dimension
Wiring Diagram
| Type |
ST2-4JD |
| L/W/H |
6.2*56*35.5 mm |
| Rated cross section |
4 mm2 |
| The minimum cross section(Rigid wire) |
0.2 mm2 |
| The maximum cross section(Rigid wire) |
6 mm2 |
| The minimum cross section(Soft wire) |
0.2 mm2 |
| The maximum cross section(Soft wire) |
4 mm2 |
| Cover |
ST3-4G |
| Jumper |
UFB 10-6 |
| Marker |
ZB6M |
| Packing unit |
100 |
| Minimum Order Quantity |
100 |
| Weight of each(not include packing box) |
12 g |
ST2-6JD
| Type |
ST2-6JD |
| L/W/H |
8.2*69.5*42.5 mm |
| Rated cross section |
6 mm2 |
| The minimum cross section(Rigid wire) |
0.5 mm2 |
| The maximum cross section(Rigid wire) |
10 mm2 |
| The minimum cross section(Soft wire) |
0.5 mm2 |
| The maximum cross section(Soft wire) |
6 mm2 |
| Cover |
ST2-6G |
| Jumper |
UFB 10-8 |
| Marker |
ZB8 |
| Packing unit |
50 |
| Minimum Order Quantity |
50 |
| Weight of each(not include packing box) |
21.5 g |
Dimension
Wiring Diagram
ST2-10JD
Dimension
Wiring Diagram
| Type |
ST2-10JD |
| L/W/H |
10.2*68*50 mm |
| Rated cross section |
10 mm2 |
| The minimum cross section(Rigid wire) |
1.5 mm2 |
| The maximum cross section(Rigid wire) |
16 mm2 |
| The minimum cross section(Soft wire) |
1.5 mm2 |
| The maximum cross section(Soft wire) |
16 mm2 |
| Cover |
ST2-10G |
| Jumper |
/ |
| Marker |
ZB10 |
| Packing unit |
50 |
| Minimum Order Quantity |
50 |
| Weight of each(not include packing box) |
33 g |
Product Tags
ST2 Earth Push In Terminal Block Related Video: